Laser protection window, filter - 0195, dimensions 210 x 297 mm, thickness 3.1 mm

Item no. 100-K0195-210x297

Product information

  • Application: Justierung (EN 208)
  • VLT (Visible light transmission): 25 %
  • Filter color: green
  • Filter material: special plastic
  • Filter thickness: 3,1 mm
  • Max. Dimensions: 1000 x 1500 mm

€98.00 without vat
€116.62 including vat

plus shipping

Shipping time in EU: up to 5 workdays

Shipping time worldwide: up to 20 workdays

Product description

Laser protection windows enable your employees to safely observe the processes in a laser system. Regardless of whether you want to integrate the laser protection windows in machine enclosures or in movable walls, we offer you the right, tested protection for your laser system, for your laser equipment and for your laser application. Depending on the desired protection level or window size, you can choose between windows made of glass or plastic. In addition to a variety of standard sizes, custom cuts are also possible thanks to our in-house production.

The laser safety filter 0195 is suitable for protection in the visible wavelength range from 600 nm. This includes HeNe (633 nm), Diodes (650 nm) and Ruby (694 nm) lasers . This filter can also be used for alignment work in the 630-700 nm range for lasers with a maximum power of 100 mW. The laser safety filter consists of a green filter made of special plastic and offers a visual light transmission (VLT) of 25% and a low filter thickness. The laser safety filter is qualified according to EN 12254.

  • dimensions 210 x 297 mm
  • also available in the standard size 100 x 200 mm and maximal size 1000 x 1500 mm
  • other customized sizes available on request
  • suitable window frames available on request 

For a perfect and safe cleaning of this filter we recommend this cleaning spray.

Further product information

Wavelengths Protection levels
180-315 D AB7 + IR AB2 (OD7+)
>315-430 D AB6 (OD6+)
>430-435 D AB5 (OD5+)
>435-440 D AB4 (OD4+)
>450-460 D AB2 (OD2+)
600-630 D AB1 (OD1+)
>630-700 D AB2 (OD2+)
>700-720 D AB1 (OD1+)
PF S CE
Wavelength [nm] Test class Max. resistance time tmax [s] Power density [kW/m²]
315 - 460 T2 110 40
Width
210
Height
297